Analog liquid level sensor - Standard type

share
WeChat
Sina Weibo
QQ
QQ space
Douban
Baidu Post Bar
Parameter
Product series
:
Analog liquid level sensor
Material
:
304/316+PTFE
Model
:
XRC - P200EA1 - G3/4M
Output
:
4 - 20mA output + 1 switching value
Medium
:
Liquids, powders, viscous media
Installation method
:
Threaded and flange installation
Power supply
:
24VDC
Display
:
LCD indicator light
Cable outlet mode
:
M12 aviation plug
xr@xrinstrument.com
Obtain quotations
Size structureConnection lineDocumentDetail

模拟量尺寸图.jpg

电气配线图

模拟量连接.jpg


模拟量产品手册(小).pdf


Technical Specifications

Electrical parameters
Operating voltage20-30VDC
Operating current<80mA
Short circuit protection (analog output)have

Reverse polarity protection (analog output)

have
0-10V outputMinimum load 5000Oh
0-20mA outputMaximum load 500Ω
4-20mA outputMaximum load 500Ω
Switch outputPNP (NO/NC switchable)
Load currentMaximum 200mA (with short-circuit protection)
Switch point settings5~95% adjustable
Measurement accuracy±3% of the maximum measurement range
Repeatability±1% of the maximum measurement range
Protection level

IP67

Temperature range
Medium temperature range-20°C to 75°C (Standard Type) -20°C to 200°C (High-temperature heat dissipation neck type)-70°C to 230°C (Amplifier split type)
Dielectric constant of dielectric≥1.8
Maximum pressure of medium3MPa(Maximum withstand pressure)   
Maximum measurement range of capacitance0~3.3nF
Electrical interface
Electrical interface4-pin M12 connector(Analog output + 1 digital output)5-pin M12 connector(Analog output + 485 communication)8-pin M12 connector(Analog output + 3 digital outputs)


① Liquid (or solid) medium; oily liquids with a dielectric constant higher than 1.8 can be measured, while the measurement accuracy of water-based liquids with a dielectric constant higher than 80 is related to the absolute length of the probe.


② Protection rating and connectors; all products have a protection rating of up to IP67. Standard products are equipped with M12 connectors.


③ Temperature and pressure; oneThe bulk liquid level sensor can operate normally in environments ranging from -20°C to +70°C. The split-type sensor with an external amplifier can withstand a maximum operating temperature of 230°C for its probe, while the maximum pressure in the container cannot exceed 10 bar.



Contact us

  • Company*

  • Address*

  • Name*

  • Email*

  • Social media*

  • Requirements*

Telephone:15624086688
Wechat
Scan