Technical Specifications
| Measuring medium | Liquid or gas (compatible with the contact material) |
| Overall Material | Membrane:316L stainless steel (contact)Process connection:316L stainless steel (contact)shell:316L stainless steelDisplay casing:ABS engineering plastic (digital tube display)Hessmann connector:ABS engineering plastic |
| Pressure range | 0~10kPa~4MPa (See range selection table for details) |
Pressure methods | gauge pressure |
| Output signal | 4-20mA, RS485 (standard Modbus-RTU protocol)(0~10VDC、0~5VDC、1~5VDC、(0.5~2.5VDC custom) |
| Power supply voltage | 8-30VDC conventional12-30VDC Standard (with display or output 0-10VDC)3~5VDC Customized (output 0.5~2.5VDC/RS485) |
| Accuracy level | 0.1%FS(Customized for measuring range ≥100kPa) 0.25%FS(Measuring range ≥ 100kPa, default)0.5%FS(10kPa≤range<100kPa Default)The meter displays a 0.5-level precision digital LED display. |
| Working conditions | Medium temperature:-40~130℃ Ambient temperature:-40~85℃ Ambient humidity:0%~95%RH (non-condensing, no dew) |
| Temperature compensation | -10~70℃(Precision is 0.25%FS, 0.5%FS, 1%FS)-40~80℃ (accuracy 0.5%FS) |
| Seismic performance | 10g(20...2000Hz) |
| Overload capacity | 200% full scale |
| Response frequency | Analog signal output ≤500Hz, digital signal output ≤5Hz |
| Stable performance | ±0.1% FS/year |
| Temperature drift | ±0.01%FS/℃ (within temperature compensation range) |
| Overall weight | No display ≈190g; with display ≈280g |
| Protection level | IP65 (no display) IP54 (display)Note: The protection level mentioned above refers to the level achieved after the electrical connection is complete. |
| Power range | Current type ≤0.02Us(W) Numeric type ≤ 0.015 Us (W) Voltage type ≤0.008Us (W) Voltage type (output 0.5~2.5) ≤0.001Us (W)Note: Us = Supply voltage |
| Load characteristics | Current-source load ≤ {(Us-7.5)÷0.02}(Us = supply voltage) ΩVoltage-type load ≥100kΩ |