Technical Specifications
| Measuring medium | Liquid or gas (compatible with the contact material) |
| Overall Material | Membrane:316L stainless steel (contact)Process connection:304 stainless steel (contact)shell:Die-cast aluminum Seals:Nitrile rubber (contact) |
| Pressure range | -100kPa~0~100MPa (See range selection table for details) |
| Pressure methods | Gauge pressure, absolute pressure, negative pressure |
| Output signal | 4-20mA, RS485 (standard Modbus-RTU protocol)(Custom sizes available: 0-10VDC, 0-5VDC, 1-5VDC) |
| Power supply voltage | 8-30VDC conventional24VDC Intrinsically safe / Dust intrinsically safe 12-30VDC Standard (with display or output 0-10VDC) |
| Accuracy level | 0.1%FS(Customized for measuring range ≥100kPa)0.25%FS(Measuring range ≥ 100kPa, default)0.5%FS(10kPa≤range<100kPa Default) 1%FS(Measuring range < 10 kPa, default) The meter displays a 0.5-level precision digital LED display. |
| Working conditions | Medium temperature:-40~85℃ Ambient temperature:0%~95%RH (non-condensing, no dew)Ambient humidity:-40~85℃ (Explosion-proof environment -20~40℃) |
| Temperature compensation | -10~70℃(Precision is 0.25%FS, 0.5%FS, 1%FS)-40~80℃ (accuracy 0.5%FS) |
| Explosion-proof type | Explosion-proof Ex d Ⅱ C T6 Gb,Intrinsically safe Ex ia ⅡC T6 Ga (current-limited output)Intrinsically safe for dust: Ex iaD 20 T80℃ (limited current output) Note: Intrinsically safe power supplies must be supplied via safety barriers or intrinsically safe power sources. |
| Seismic performance | 10g(20...2000Hz) |
| Overload capacity | 200% full scale or 120MPa (whichever is lower) |
| Response frequency | Analog signal output 10-2400Hz, digital signal output 10Hz |
| Stable performance | ±0.1% FS/year |
| Temperature drift | ±0.01%FS/℃ (within temperature compensation range) |
| Overall weight | ≈900g |
| Protection level | Standard IP65Explosion-proof IP66Intrinsically safe IP65Intrinsic safety IP66 for dust Note: The protection level mentioned above refers to the level achieved after the electrical connection is complete. |
| Power range | Current type ≤0.02Us(W)Numeric type ≤ 0.015 Us (W)Voltage type ≤0.008Us (W)Note: Us = power supply voltage |
| Load characteristics | Current-source load ≤ {(Us-7.5)÷0.02}(Us = supply voltage) Ω Voltage-type load ≥100kΩ |