Technical parameter table
| Output signal | DC4 - 20mA + HART protocol |
| Output mode | Linear outputSquare root output (can be remotely adjusted via configuration software) |
| Measurement range | Rated range 0 - 6.2~40KPa0 - 31.1~250KPa0 - 0.117~1MPa 0 - 0.345~2.5MPa Single - end maximum static pressure10Mpa10Mpa10Mpa13Mpa |
| Zero point and range | Can be adjusted using the local range and zero buttons, or remotely adjusted using a HART handheld intelligent terminal |
| Zero positive and negative migration | When performing zero negative migration, the lower limit of the range must be greater than or equal to -URL; when performing zero positive migration, the upper limit of the range must be less than or equal to +URL.The verification range must be greater than or equal to the lower limit of the range |
| Damping time constant | The time constant is adjustable, increasing in increments of 0.1 seconds, from a minimum of 0 to 32 seconds. If the damping time is 0, it defaults to 0.1 seconds |
| Environmental temperature limit | Ordinary type: -40 to 85℃, LCD display: -20 to 70℃ |
| Process temperature limit | -40 to 104℃ |
| Storage temperature limit | -40 to 85℃ |
| Environmental humidity | 0 - 95% relative humidity |
| Volume change | Less than 0.01in3 (0.16cm)3 (Under the reference conditions of the zero - reference calibration range, filled with silicone oil, 316L stainless steel isolation diaphragm) |
| Accuracy | Range ratio < 5:1: ≤ ±0.1 % FSRange ratio ≥ 5:1: ≤ ±0.25 % FS |
| Stability | % FSStability6 |
| Environmental temperature influence | -29 to 85℃, zero error: 0.5%URL/56℃, overall error: (0.5%URL + 0.2% verification range) /56℃ |
| Vibration influence | In any axial direction, the vibration influence at 200Hz is 0.2%URL/g |
| Power supply range | 8 - 30VDC |
| Intrinsic safety explosion - proof | Ex ia ⅡC T6 Ga Note: Intrinsic safety must be powered by a safety barrier or an intrinsically safe power supply |
| Installation position influence | The zero - point drift is at most ±0.25Kpa. All zero - point drifts can be corrected; there is no influence on the range |
| Load influence | There is no load influence, unless the power supply voltage changes |
| Load characteristics | Current - type load ≤ {(Us - 12)÷0.02 (Us = supply voltage)}Ω |